Posted in

How to choose between air and gas-insulated low voltage switchgear?

As a low voltage switchgear supplier, I’ve spent the last decade talking to facility managers, electrical engineers, and plant operators who stare down the same crossroads every time they spec new distribution gear: air-insulated switchgear (AIS) or gas-insulated switchgear (GIS). It’s not a choice you make on a hunch—pick the wrong one, and you’re looking at higher long-term costs, compliance headaches, or even safety risks. I’ve walked teams through this decision more times than I can count, and today I’m breaking down what actually matters, no sales fluff, just the practical stuff I’ve learned on the job. Low Voltage Switchgear

Let’s start with the basics to make sure we’re all on the same page. Low voltage switchgear, the gear that controls, protects, and isolates electrical power in commercial buildings, factories, and data centers, comes in two primary insulation types. AIS uses ambient air as the insulating medium between live electrical parts. It’s been the workhorse of the industry for over a century—think of it as the old, reliable pickup truck of switchgear. GIS, on the other hand, uses a potent sulfur hexafluoride (SF6) gas, or in newer models, eco-alternatives like C4-perfluoroketone, to insulate those same live parts. That’s the sleek, compact SUV that’s great for tight spaces but comes with a few unique tradeoffs.

The first big factor anyone needs to weigh is physical space. I can’t tell you how many times a plant operator has called me panicking because their new production line shoved their existing switchgear footprint right up against the wall. If your room or vault is maxed out, GIS is almost always the answer. On average, GIS takes up 30 to 50 percent less floor space than an equivalent AIS unit. Why? Because SF6 has 2.5 times higher dielectric strength than air. That means the live parts can be packed much closer together without the risk of arcing or short circuits. Last year, I worked with a food processing plant in the Midwest that was expanding their canning line and didn’t have an inch of extra room in their existing electrical vault. We installed a set of medium-to-low voltage GIS units that fit in the same space as their old AIS, giving them the power capacity they needed without a single costly vault renovation. But space isn’t just about square footage—height matters too. AIS units are often taller because of the longer air gaps required for insulation, so if you have low ceiling clearances, GIS will be easier to integrate.

Next up is cost, and this is where most people get tripped up. There’s upfront cost, and there’s lifetime cost, and they often tell very different stories. Let’s start with upfront: AIS is almost always cheaper to buy. The materials are simpler—just metal cabinets, bare busbars, and air for insulation—so manufacturing costs are lower. A basic 1000A AIS unit might run 15 to 25 percent less than an equivalent GIS unit. But here’s the catch: that’s just the sticker price. GIS has a much smaller footprint, so if you have to renovate or build a new room to fit AIS, the upfront cost gap closes fast. I saw this with a retail chain that was building a new 10-story flagship store in downtown Chicago. Their original spec was AIS, but when we ran the numbers, the cost to dig out an extra 2 feet of vault space and install fire protection for AIS added $120,000. Switching to GIS cut that vault work by 70 percent, making the total project cost lower, even though the GIS units themselves were more expensive.

Now the lifetime costs. AIS is way cheaper to maintain long-term. You can open an AIS cabinet, inspect the busbars and breakers with a simple thermal camera, wipe down the interior, and test the insulation in minutes. Most AIS maintenance is done with basic tools that every electrician already has. GIS? That’s where it gets complicated. SF6 is a potent greenhouse gas—23,500 times more impactful than CO2 over a 100-year period—so regulatory rules around handling, testing, and leak checking are strict. You can’t just pop open a GIS cabinet on a Tuesday afternoon. If you need to test for gas leaks, you need specialized equipment, and if you have to top up or replace SF6, that’s a licensed process. New eco-GIS models have reduced that burden, but they still cost 20 to 30 percent more to service than AIS, and most maintenance techs need extra training to work on them. Also, don’t forget outage costs. If AIS needs maintenance, you can schedule a shorter outage because the work is faster. GIS work often requires longer outages because of the specialized steps around gas handling.

Safety is another non-negotiable factor, and it’s not just about the live parts. Let’s start with arc flash risk, which is one of the biggest hazards in electrical work. Arc flash is the explosion of heat and energy that happens when live parts come into contact, and it can reach temperatures of 35,000°F—hotter than the surface of the sun. Studies from the Electrical Safety Foundation International (ESFI) have found that AIS units have a higher arc flash boundary than GIS units, meaning workers stand further away from danger when working on AIS. Why? The air insulation creates a larger gap for the arc to spread, while the dense SF6 in GIS quenches arcs much faster, limiting their size. That said, GIS has its own safety risks. If SF6 leaks into an enclosed space, it’s odorless and heavier than air, so it can build up at floor level and displace oxygen, leading to suffocation without any warning signs. I always make sure every GIS installation I sell has integrated oxygen monitoring and ventilation systems, because that risk is real. For facilities with a lot of foot traffic around electrical gear, or where maintenance techs work on the equipment daily, that lower arc flash risk of GIS can be a big win.

Environmental impact is more important now than ever, and I get a lot of questions about this from clients focused on sustainability. Traditional SF6 GIS has a huge carbon footprint, which is why many regulations now require strict leak reporting and tracking. For example, the EU’s F-Gas Regulation limits SF6 use in new equipment unless it’s for critical applications, and many US states are rolling out similar rules. If you’re a company with net-zero targets, that’s a big red flag for traditional SF6 GIS. The good news is that modern eco-GIS uses alternative gases that have less than 1% of the global warming potential of SF6. These models are fully compliant with strict environmental rules, and most don’t require the same level of gas leak monitoring. But they’re still newer, so the supply chain is more limited, and they cost more upfront. AIS, on the other hand, has a tiny carbon footprint over its lifecycle—air is free, no harmful gases, and disposal is straightforward, just metal parts that can be recycled. For factories or data centers that care deeply about their ESG scores, AIS is often the simpler, more sustainable choice, as long as space and safety requirements aren’t dealbreakers.

Lifespan and reliability are also key. Both AIS and GIS are built to last, with average lifespans of 30 to 40 years when properly maintained. But their failure modes are different. AIS is more prone to issues like dust buildup, corrosion on busbars, and small air gaps that get wider over time due to temperature changes. These issues are easy to catch during routine maintenance, though. GIS, because it’s sealed, has fewer opportunities for contaminants to get inside, so it’s more reliable in harsh environments. Wait, harsh environments—let’s talk about that. If your switchgear is going in a place with high humidity, salt air, dust, or extreme temperature swings, AIS can suffer from corrosion and insulation breakdown over time. GIS, being sealed, is much more resistant to these environmental factors. Last year, I worked with a port facility in Houston that had a switchgear room right next to the dock, with constant salt spray and high humidity. They tried AIS once, and corrosion on the busbars caused three unplanned outages in six months. Swapping to sealed GIS fixed that—they haven’t had a corrosion-related issue since. But if you have a clean, controlled indoor environment, AIS is just as reliable, and easier to troubleshoot when something does go wrong.

Training and accessibility are two practical factors that people don’t always think about until it’s too late. How many trained techs do you have on staff, and how often do they work on switchgear? If your team only has experience with old AIS units, bringing in GIS will require time and money for specialized training. Most small to medium businesses don’t have dedicated electrical maintenance teams that can spare a week or two to learn GIS service protocols. On the flip side, if you have a large engineering team that works with multiple types of equipment, and you want a compact solution that requires less hands-on maintenance, GIS might be worth the training cost. I always advise clients to check their local talent pool too. In many rural areas, there are fewer technicians certified to work on SF6 or eco-GIS, so finding someone to service your gear when you need it can be a challenge. AIS, on the other hand, is universal—any licensed electrician should be able to work on it, no extra certifications required.

Let me give you a real example to tie this all together. A few months ago, I met with the operations manager of a 50,000 square foot pharmaceutical warehouse in Kansas City. They were expanding their cold storage area, which needed a 20% power upgrade, and their existing electrical vault had only 15 square feet of free space—just enough to fit one more unit, not two. Their options: 2 AIS units, which would require adding a 20 square foot extension to the vault (costing $85,000 upfront) and have higher long-term maintenance costs, or 1 GIS unit that fit in the existing space, with a slightly higher upfront cost but lower outage risk for their temperature-sensitive products. We also checked their sustainability goals—they were aiming for B Corp certification, so the SF6 footprint was a concern. We ended up going with an eco-GIS unit: it fit, required no vault extension, had a lower arc flash risk for their maintenance team, and the new eco-gas met their ESG requirements. The client was thrilled—no extra construction, no downtime during installation, and the unit checked all their boxes for safety and sustainability.

Another example: a small manufacturing shop in Detroit that was upgrading their power for new machinery. They had a spacious electrical room, a small budget, and a general maintenance team that had been working on AIS for 20 years. We recommended AIS. It was cheaper upfront, their team knew how to service it, and there was plenty of space. Five years later, they’ve had zero issues, and maintenance has cost a fraction of what they would have paid for GIS.

So, how do you actually make the choice? Let’s boil it down to a quick decision framework. First, measure your available space. If you’re tight on room, GIS is the go-to. Second, calculate your total cost of ownership, not just the upfront price—include maintenance, potential construction for AIS, and training. Third, assess safety needs: if your team works on the equipment daily, or you’re in an enclosed space where gas leaks are a risk, weigh the arc flash benefits of GIS against the suffocation risk of SF6. Fourth, check regulatory and sustainability rules—if you’re in a region with strict F-Gas regulations, eco-GIS or AIS might be required. Fifth, look at your in-house expertise and local talent—if you don’t have access to certified GIS techs, AIS is the safer bet long-term.

At the end of the day, there’s no “best” choice between AIS and GIS—only the best choice for your specific facility, budget, and needs. As a low voltage switchgear supplier, I don’t push one over the other. My job is to give you the facts, walk through the tradeoffs, and help you pick a solution that works for you, not just one that has a higher profit margin for my business. If you’re in the market for new switchgear, or you’re trying to work through this decision for an upcoming project, I’d be happy to sit down with you, walk through your space, budget, and goals, and give you a personalized recommendation that makes sense for your team.

Fixed Type Switchgear References

  1. Electrical Safety Foundation International (ESFI). (2022). Arc Flash Risk Mitigation in Low Voltage Switchgear.
  2. International Electrotechnical Commission (IEC). (2021). Standard for Gas-Insulated Switchgear for Low Voltage Applications.
  3. U.S. Environmental Protection Agency (EPA). (2023). SF6 Emission Reduction Guidelines for Electrical Equipment.
  4. National Fire Protection Association (NFPA). (2022). 70B: Recommended Practice for Electrical Equipment Maintenance.

Zhejiang Dongyu Electric Co., Ltd.
As one of the most professional low voltage switchgear manufacturers and suppliers in China, we’re featured by quality products and good price. Please rest assured to buy customized low voltage switchgear made in China here from our factory. Also, pricelist is available.
Address: No.11 Baoqiao Road, Huaxi Industrial Park, Changxing County, Zhejiang Province
E-mail: dongyu178@163.com
WebSite: https://www.dongyuswitch.com/