{"id":3653,"date":"2026-11-10T14:55:45","date_gmt":"2026-11-10T06:55:45","guid":{"rendered":"http:\/\/www.baaclottobet.com\/blog\/?p=3653"},"modified":"2026-11-10T14:55:45","modified_gmt":"2026-11-10T06:55:45","slug":"what-is-the-turn-on-time-of-an-igbt-module-44d6-1a2e25","status":"publish","type":"post","link":"http:\/\/www.baaclottobet.com\/blog\/2026\/11\/10\/what-is-the-turn-on-time-of-an-igbt-module-44d6-1a2e25\/","title":{"rendered":"What is the turn &#8211; on time of an IGBT module?"},"content":{"rendered":"<p>Alright, let\u2019s talk about something that comes up all the time when customers reach out to us as an IGBT module supplier: the turn-on time of an IGBT module. I get a lot of questions from folks who are designing power systems, motor drives, solar inverters\u2014you name it\u2014and most of the time, they\u2019re not just asking out of curiosity. They need to know this number because it directly impacts how their system performs, how efficient it is, and even how long the whole thing will last. <a href=\"https:\/\/www.zdservo.com\/igbt-module\/\">IGBT Module<\/a><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/www.zdservo.com\/uploads\/47703\/page\/small\/micro-motor-driverd26e9.jpg\"><\/p>\n<p>First off, let\u2019s keep it real. Turn-on time isn\u2019t some random spec we pull out of a datasheet to make our modules look good. It\u2019s a critical parameter that describes exactly how long it takes for an IGBT to go from being fully off (no current flowing through it) to fully on (conducting as much current as it can handle under the given conditions). Simple enough, right? But here\u2019s where it gets tricky: turn-on time isn\u2019t a fixed number. It changes depending on a bunch of factors, and that\u2019s something I wish more people understood before they start comparing modules from different suppliers.<\/p>\n<p>Let me break it down a little. When you send a gate signal to the IGBT\u2019s gate terminal, that\u2019s the start of the turn-on process. The gate has a capacitance, so you can\u2019t just flip a switch and have the IGBT conduct instantly. You have to charge that gate capacitance first\u2014from the initial off state, where the collector current is zero, to the point where the IGBT enters the saturation region (fully on). That whole process is split into two parts, actually. There\u2019s the delay time (t_d(on))\u2014that\u2019s the time it takes for the collector current to start rising after you apply the gate signal\u2014and then the rise time (t_r), which is how long it takes for the collector current to jump from 10% of its rated value to 90% of it. Add those two together, and that\u2019s your total turn-on time (t_on = t_d(on) + t_r). That\u2019s the basic definition, but let\u2019s not get too bogged down in the math here.<\/p>\n<p>As a module supplier, I\u2019ve seen customers get confused because datasheets often list turn-on time at a specific test condition\u2014like a given gate resistance, collector current, and voltage. But in the real world, their application might not match that test setup. For example, if you\u2019re using our modules in a high-power motor drive, the collector current is going to be a lot higher than the 50A they used in the datasheet test. What happens then? Turn-on time gets slower. Why? Because when you\u2019re pushing more current, you need to charge that gate capacitance more, and the carriers inside the IGBT\u2019s semiconductor material take longer to build up enough to switch fully on. It\u2019s like trying to fill a big bucket vs. a small one\u2014takes more time for the big one.<\/p>\n<p>Another big factor is gate resistance (R_g). A lot of people don\u2019t realize that the gate resistor you choose has a direct impact on turn-on time. If you use a lower R_g, you\u2019re charging the gate capacitance faster, so turn-on time is shorter. But wait\u2014there\u2019s a catch there. Go too low, and you might get excessive voltage spikes or current overshoot during turn-on, which can damage the module over time. As a supplier, we work closely with customers to pick the right R_g for their needs: if they care about fast switching (like in high-frequency inverters), we might suggest a lower R_g, but we always warn them about the tradeoffs. If they need more stability and less stress on the module, a slightly higher R_g is better, even if turn-on time is a bit longer.<\/p>\n<p>Temperature also plays a huge role, and this is one area where cutting corners on module quality really shows. At low temperatures, the semiconductor material (silicon, for most standard IGBTs) has more resistance to carrier movement, so turn-on time is longer. At high temperatures, carriers move faster, so turn-on time is shorter. But here\u2019s the thing: some cheap modules from overseas suppliers don\u2019t specify temperature-dependent turn-on time, which can lead to bad design choices. Our modules, though\u2014we test turn-on time at both -40\u00b0C and 125\u00b0C (and sometimes higher, for extreme applications) so our customers know exactly what to expect no matter where their system is operating.<\/p>\n<p>Now, why does turn-on time matter in the first place? Let\u2019s take a solar inverter as an example. If your IGBT turns on too slowly, the inverter\u2019s efficiency drops because you\u2019re wasting energy during the time the IGBT is transitioning between on and off. That\u2019s lost power the customer can\u2019t make back. On the flip side, if turn-on time is too fast, you get those big current spikes, which can cause electromagnetic interference (EMI) problems or even shorten the module\u2019s lifespan. As a supplier, we pride ourselves on balancing these two. Our modules have turn-on times optimized for the application\u2014whether that\u2019s a low-speed motor drive where efficiency is key or a high-frequency servo drive where fast switching is needed.<\/p>\n<p>I also get asked a lot about how turn-on time compares to turn-off time. They\u2019re related, but different. Turn-off time is about how long it takes for the IGBT to go from fully on to fully off, and it includes a tail current phase, which is a big factor in switching losses. Turn-on time is more about the initial transition, but both are tied together\u2014you can\u2019t just optimize one without considering the other. For example, a module with very fast turn-on time might have a longer turn-off time, which could be a problem in applications where you need quick off switching to prevent short circuits.<\/p>\n<p>Another common mistake I see: customers use the turn-on time from a small IGBT sample, then use it for a whole series of modules. But as IGBT power increases, the turn-on time changes. A 100A module will have a different turn-on time than a 500A module, even from the same product line. We make sure our datasheets clearly distinguish between different current ratings, so you\u2019re not comparing apples to oranges. If you\u2019re not sure which spec applies to your design, just reach out\u2014our engineers are here to help, no hard sell, just honest advice.<\/p>\n<p>Let\u2019s talk about some real-world examples. Last quarter, we had a customer who was building a new electric forklift. They were using a competitor\u2019s module, and their forklift was overheating and losing battery life faster than expected. They sent over their design, and we found out that the competitor\u2019s module had a turn-on time that was 20% longer at their operating current. That extra time meant more switching losses, which translated to more heat and less battery efficiency. We supplied them with our modules, and within a month, they reported a 15% increase in battery runtime and a 10% drop in operating temperature. That\u2019s the kind of impact turn-on time has\u2014it\u2019s not just a number; it\u2019s the difference between a good product and a great one.<\/p>\n<p>Now, I should mention that there\u2019s no such thing as a \u201cperfect\u201d turn-on time. What\u2019s ideal depends entirely on your application. If you\u2019re designing a high-frequency induction heater, you need turn-on time as short as possible to maximize efficiency. If you\u2019re designing a grid-tie inverter, you might prioritize lower EMI over the absolute fastest turn-on time. That\u2019s why it\u2019s so important to work with a supplier who understands your specific needs, not just someone who spouts generic datasheet numbers.<\/p>\n<p>As a supplier, we also provide application notes that walk through how to calculate turn-on time for your specific setup. We include formulas that take into account your gate resistance, collector current, and temperature, so you don\u2019t have to guess. A lot of customers don\u2019t know that we offer this\u2014it\u2019s not something we advertise a lot, but it\u2019s how we build trust. We want our customers to succeed, not just buy a module and hope it works.<\/p>\n<p>One more thing: aging. Turn-on time isn\u2019t the same when the module is new vs. after 5 or 10 years of use. As the IGBT ages, the gate capacitance changes slightly, which can make turn-on time a bit longer. That\u2019s normal, but it\u2019s something we factor into our reliability testing. Our modules go through accelerated aging tests to ensure that even after 10 years, turn-on time is still within the spec you designed for. Cheaper modules might have a bigger shift in turn-on time over time, leading to unexpected system failures.<\/p>\n<p>So, to wrap this up: turn-on time is a key IGBT module spec that describes how fast the device switches from off to on. It\u2019s not fixed\u2014it depends on current, gate resistance, temperature, and module design. It impacts efficiency, heat, EMI, and overall system lifespan. As an IGBT module supplier, our job isn\u2019t just to sell you a module with a fast turn-on time\u2014it\u2019s to give you the right turn-on time for your application, and to provide the support you need to make that work.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/www.zdservo.com\/uploads\/47703\/small\/robot-arm-jointe8245.jpg\"><\/p>\n<p>If you\u2019re in the market for IGBT modules and you\u2019re not sure which turn-on time is right for your design, or if you\u2019ve been having issues with your current modules\u2019 switching performance, get in touch. We\u2019re here to answer your questions, walk through your application, and help you find the perfect module for your needs. Don\u2019t hesitate to reach out\u2014we\u2019d love to work with you.<\/p>\n<p><a href=\"https:\/\/www.zdservo.com\/robot-joints\/\">Robot Joints<\/a> REFERENCES<\/p>\n<ol>\n<li>&quot;IGBT Modules: Application and Design Considerations&quot; \u2013 Infineon Technologies AG<\/li>\n<li>&quot;Power Semiconductor Devices: IGBTs for Industrial Applications&quot; \u2013 Mitsubishi Electric Corporation<\/li>\n<li>&quot;Fundamentals of Power Electronics&quot; \u2013 R.W. Erickson and D. Maksimovic<\/li>\n<\/ol>\n<hr>\n<p><a href=\"https:\/\/www.zdservo.com\/\">Hangzhou Zhongda Motor Co., Ltd.<\/a><br \/>We&#8217;re well-known as one of the most professional IGBT module manufacturers in China, also support customized service. Please feel free to buy bulk high quality IGBT module made in China here from our factory. Contact us for pricelist.<br \/>Address: NO 111.Dalingshan Road,Yinhu Street,Fuyang District,Hangzhou City,Zhejiang Rrovince,China.<br \/>E-mail: admin@hz-zhijue.com<br \/>WebSite: <a href=\"https:\/\/www.zdservo.com\/\">https:\/\/www.zdservo.com\/<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Alright, let\u2019s talk about something that comes up all the time when customers reach out to &hellip; <a title=\"What is the turn &#8211; on time of an IGBT module?\" class=\"hm-read-more\" href=\"http:\/\/www.baaclottobet.com\/blog\/2026\/11\/10\/what-is-the-turn-on-time-of-an-igbt-module-44d6-1a2e25\/\"><span class=\"screen-reader-text\">What is the turn &#8211; on time of an IGBT module?<\/span>Read more<\/a><\/p>\n","protected":false},"author":33,"featured_media":3653,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[3616],"class_list":["post-3653","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-industry","tag-igbt-module-4a12-1a644c"],"_links":{"self":[{"href":"http:\/\/www.baaclottobet.com\/blog\/wp-json\/wp\/v2\/posts\/3653","targetHints":{"allow":["GET"]}}],"collection":[{"href":"http:\/\/www.baaclottobet.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"http:\/\/www.baaclottobet.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"http:\/\/www.baaclottobet.com\/blog\/wp-json\/wp\/v2\/users\/33"}],"replies":[{"embeddable":true,"href":"http:\/\/www.baaclottobet.com\/blog\/wp-json\/wp\/v2\/comments?post=3653"}],"version-history":[{"count":0,"href":"http:\/\/www.baaclottobet.com\/blog\/wp-json\/wp\/v2\/posts\/3653\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"http:\/\/www.baaclottobet.com\/blog\/wp-json\/wp\/v2\/posts\/3653"}],"wp:attachment":[{"href":"http:\/\/www.baaclottobet.com\/blog\/wp-json\/wp\/v2\/media?parent=3653"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"http:\/\/www.baaclottobet.com\/blog\/wp-json\/wp\/v2\/categories?post=3653"},{"taxonomy":"post_tag","embeddable":true,"href":"http:\/\/www.baaclottobet.com\/blog\/wp-json\/wp\/v2\/tags?post=3653"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}